ABB 500AIM02 Analog Input Unit 1MRB150022 R0002 1HDF 930412 X010 — REC 580 Bay Terminal Spare
| Item | Detail |
|---|---|
| Order code breakdown | 1MRB150022 is the base ordering number for the analog input unit; the R0002 block marks the hardware revision supplied under that number |
| Type designation | 500AIM02, marked on the front plate next to the order code |
| Drawing reference | 1HDF 930412 X010, the type drawing that fixes the layout and terminal assignment for this build |
| Where it goes | Plugged into a module position in the rack of an REC 580 bay control terminal |
| What it accepts | Analog outputs from the 500MTM02 transformer module or the 500ITM02 isolating amplifier, up to 16 signals per card |
| Signal handling | Anti-alias filtering, 16-bit conversion at 1.0 or 1.2 kHz, DSP pre-processing, then handover to the processor module |
| Channel separation | Differential inputs with channel-to-channel insulation, so a current channel and a voltage channel can be neighbours without interference |
| Rack limits | Two cards maximum per rack, which caps the terminal at 32 analog signals per rack before an extension rack is needed |
| Power draw | 6 W from the rack, no separate supply wiring of its own |
| Interchange notes | R0002 builds are form-and-fit interchangeable with the other revisions of the same base number, but the 1HDF drawing must match the terminal build |
| Buying signals | Sold in the low hundreds rather than the module bracket; sellers quoting PLC or AC500 compatibility are describing a different product line |
| Practical check on arrival | Confirm the front plate reads 500AIM02 and the label carries both the 1MRB and 1HDF codes before fitting |