Description
ABB 5SHX1060H0002 IGCT Module – 6 kV / 600 A Reverse-Conducting Gate-Commutated Thyristor for ACS1000 Medium-Voltage Drives
| Parameter | Value |
|---|---|
| Device type | Reverse-conducting IGCT, press-pack, integrated gate unit, monolithic free-wheeling diode |
| ABB type designation | 5SHX1060H0002 |
| Ordering code | 3BHL000388P0101 (replaces HL000388P0101) |
| Repetitive peak off-state voltage, VDRM | 6000 V (6 kV class) |
| Pole-piece (contact) diameter | 68 mm |
| Max. average on-state current, ITAVM | 600 A |
| Max. controllable turn-off current, ITGQM | 1000 A |
| Free-wheeling diode | Monolithically integrated (reverse-conducting design, no external diode) |
| Gate unit supply | 24–40 V AC square wave or DC, ≤ 100 W |
| Control interface | Fibre-optic command input with optical status feedback |
| Cooling / mounting | Double-side cooled, press-pack clamped to heatsink |
| Net weight | 2.11 kg |
| Package dimensions (L × W × H) | 240 × 199 × 61 mm |
| Country of origin / customs tariff | Czechia (CZ) / CN8 85413000 |

ABB IGCT Module | ABB ACS6000 | ABB PCS6000 | 5SHY

ABB IGCT Module | ABB ACS6000 | ABB PCS6000 | 5SHY

ABB IGCT Module | ABB ACS6000 | ABB PCS6000 | 5SHY
Typical platforms: ACS1000, ACS2000 and ACS6000 medium-voltage drives, current-source inverters and grid power-quality equipment.