Description
ABB 5SHY 35L4512 Asymmetric IGCT Power Module — 4500 V / 4000 A, Order Code 3BHE014105R0001
| Attribute | Rating |
|---|---|
| Device type | Asymmetric integrated gate-commutated thyristor (IGCT), press-pack GCT with integrated gate unit |
| ABB type designation / order code | 5SHY 35L4512, 4500 V / 4000 A class — order code 3BHE014105R0001 |
| Repetitive peak off-state voltage VDRM | 4500 V, gate unit energized |
| Permanent DC-link voltage VDC-link | 2800 V, 100 FIT failure rate of GCT at sea level |
| Max. controllable turn-off current ITGQM | 4000 A at Tvj = 125 °C, VD = 2800 V, RS = 0.65 Ω |
| Max. average / RMS on-state current | 2100 A average (half sine, TC = 85 °C, double side cooled) / 3300 A RMS |
| Peak non-repetitive surge current ITSM | 35 kA at 10 ms, 23 kA at 30 ms, Tvj = 125 °C; I²t 6.1 × 10⁶ A²s |
| On-state voltage VT / threshold V(T0) / slope rT | 1.8 V typ., 2.0 V max. at 4000 A, 125 °C / 1.15 V / 0.21 mΩ |
| Turn-off energy per pulse Eoff | 26 J typ., 37 J max. |
| Mounting force / weight / pole-piece diameter | 40 kN nominal (36–44 kN) / 2.9 kg / Ø85 mm |
| Operating junction / storage temperature | −40 °C to +125 °C junction, −40 °C to +60 °C storage |
| Thermal resistance Rth(j-c) / Rth(c-h) | 8.5 K/kW / 3 K/kW, double side cooled |
| Gate unit supply / consumption | 28–40 V AC square wave (15–100 kHz) or DC, ≤100 W, current limit 8 |