Description
ABB 5SHY3545L0016 3BHB019719R0101 IGCT Module
The 5SHY 3545L0016 is an asymmetric IGCT of the 4.5 kV, 91 mm class used in ACS 6000 phase modules, built for a 2800 V DC link and snubberless turn-off. It clips into a press-pack stack between water-cooled heat sinks and is driven by an external gate unit over plastic optical fibre. On this version ABB notes that only one of the two fibre channels is used, the receiving one, so the transmitter lead stays unconnected.
| Parameter | Value |
|---|---|
| Type designation | 5SHY 3545L0016, asymmetric IGCT |
| Order code | 3BHB019719R0101, superseded by 3BHB020720R0002 and then 3BHB030310R0001 |
| Blocking voltage | 4500 V repetitive peak off-state, ≤50 mA off-state current |
| DC link voltage | 2800 V permanent DC for 100 FIT failure rate |
| On-state current | 1700 A average at 85 °C case, 2700 A RMS |
| Turn-off current | 4000 A controllable turn-off current |
| Surge current | 32 kA for 10 ms, 12 kA for 100 ms |
| On-state voltage | ≤2.70 V at 4000 A; threshold 1.40 V, slope resistance 0.325 mΩ |
| Switching | Turn-on delay ≤3 µs, turn-off delay ≤7 µs, turn-off energy ≤18 J |
| Gate unit | 24–40 V AC supply, ≤100 W, status feedback over 1 mm optical fibre, LED diagnostics |
| Mechanical data | 85 mm pole piece, 26 mm housing, 439 × 172.5 × 40 mm, 2.9 kg |
| Clamping force | 36 kN minimum, 40 kN nominal, 44 kN maximum |
| Thermal | Junction −40 to 125 °C, 8.5 K/kW junction to case, 3 K/kW case to heat sink |
| Service note | Order the current replacement code rather than the old one, keep the gate unit paired with the device, and follow the dual-use export paperwork |