ABB DSCA114 57510001-AA | Asynchronous communication board

$3,780.00

ABB identifies part number 57510001-AA as the DSCA 114 asynchronous communication board, with an RS-232/V.24 interface.
Brand model:ABB 
Product Name:DSCA 114 57510001-AA
Warranty: 1 year
Origin:USA
HS code:85389000.00
Inventory: Spot/Futures
Goods condition: Brand new
Delivery time: 3-4days/1month

Brand: Model/SKU: ABB DSCA114 57510001-AA

Description

  • Brand: ABB
  • Model: DSCA114
  • Full Part Number: 57510001-AA
  • Lifecycle Status: Confirm current lifecycle status with ABB
  • Core Function: Asynchronous communication board for industrial process control
  • Communication Interface: RS-232 / V.24
  • System Association: ABB Advant Master Process Control System; MasterPiece 200 and 200/1 applications
  • Top Technical Specs: Asynchronous serial communication; RS-232/V.24 interface; product-specific configuration requires verification
  • Stock and Condition: Confirm physical stock, condition, and dispatch date before ordering
  • Warranty: Confirm the applicable warranty in the quotation

ABB identifies part number 57510001-AA as the DSCA 114 asynchronous communication board, with an RS-232/V.24 interface.

 

Migration, Compatibility and Field Traps

Replacement Matrix

Evaluation Item Engineering Guidance
Replacement classification Exact-part replacement candidate; confirm 57510001-AA
Drop-in replacement Conditional on matching hardware revision, system position, and connections
Software compatibility Verify controller configuration and serial communication settings
Hardware modification Not expected for an identical, correctly configured replacement; verify the installed assembly
Communication interface RS-232/V.24 asynchronous serial
Lifecycle status Confirm current availability and lifecycle status
Commissioning requirement Validate communication with the connected device before returning the system to service

Field Traps: Watch Out

  • Serial Configuration Mismatch: Check baud rate, data bits, parity, stop bits, and handshaking requirements at both ends of the communication link. A physical connection alone does not establish protocol compatibility.
  • Connector and Signal Assignment: Confirm connector pin assignments, signal reference, cable wiring, and interface requirements against the applicable ABB documentation. Incorrect wiring can prevent communication or damage connected equipment.

Before installation, isolate the relevant equipment according to site procedures and use appropriate electrostatic-discharge precautions. After replacement, verify data exchange and confirm that the controller reports the expected communication status.

ABB Advant Master -S100 I_O System

ABB Advant Master -S100 I_O System

ABB Advant Master -S100 I_O System

ABB Advant Master -S100 I_O System

ABB Advant Master -S100 I_O System

ABB Advant Master -S100 I_O System

Quality Assurance and Testing SOP

The inspection scope should reflect the unit’s quoted condition and the test facilities available. The following checks define the requested pre-shipment process; do not claim successful completion without unit-specific records.

  • OEM Identification Inspection: Verify the ABB nameplate, DSCA114 model designation, 57510001-AA part number, revision markings, and available traceability records.
  • Physical Inspection: Examine the PCB, connector contacts, solder joints, components, and mounting points for corrosion, damage, contamination, or signs of unauthorized repair.
  • Anti-Counterfeit Screening: Compare product markings and construction details with available OEM references. Record any identification discrepancies for review.
  • Power-On Assessment: Where an approved fixture is available, apply the specified operating conditions and document observed diagnostic indicators. Do not assume a particular LED sequence without the applicable manual.
  • Serial Communication Test: Connect the board to a suitable test setup and verify asynchronous RS-232/V.24 communication using documented settings.
  • Data Exchange Verification: Transmit and receive test data where supported by the test arrangement. Record communication errors, connection stability, and the test configuration.
  • Final Inspection: Recheck the part number, physical condition, order quantity, and packaging before dispatch. Protect the board against electrostatic discharge during handling and transit.

QA release criterion: Record the test scope, results, limitations, and inspection date. If powered communication testing is unavailable, disclose that limitation clearly rather than representing visual inspection as a full functional test.

ABB 500CIM05 1MRB150077R1B | Direct Replacement for P13/P14 System Bus Modules
ABB 500BIO01 1MRB150005R1J Binary I/O Module Full Product Page
ABB PM865 3BSE030193R1 | Direct Replacement for AC800M System Control Units
ABB XUD194 3BHE018137R0001 | AC800PEC Product Page
ABB 500CPU05 1MRB150081R1E Industrial PLC CPU Module
ABB HS810 3BDH000305R0101 | Safety Module Full Product Page
ABB DASO110 57120001-AT1 | Genuine ABB Process Control I/O For Valves & Actuators
ABB SUE3000 1VCR007346 G0032 | HMI Operator Unit for SUE3000 Medium Voltage High Speed Bus Transfer System
mingpian
xcd