Description
ABB GBU72 Grid Breaker Unit – 3BHE055094R0002 Medium-Voltage Grid Disconnect and Earthing Unit for PCS6000 Wind Converters
| Parameter | Value |
|---|---|
| Product type | Grid Breaker Unit (GBU), integrated unit of the ABB PCS6000 medium-voltage full-power converter |
| ABB type designation | GBU72 |
| Ordering code | 3BHE055094R0002 |
| Main function | Making, breaking and short-circuit breaking on the grid side of the converter |
| Included switching devices | Grid circuit breaker plus three-position disconnector on a common mounting plate |
| Disconnector positions | Closed / test / earthed (earthing completed by closing the breaker with the switch in earth position) |
| Operating mechanism | Motor-operated, with hand cranks for emergency manual operation and earthing |
| Rated grid-side voltage | 3.3 kV |
| Insulation level | U0 / U = 6 / 10 kV (IEEE 5 / 8 kV) |
| dv/dt at converter terminals | < 2.5 kV/µs, supported by the integrated dv/dt filter module |
| Grid-side cable connection | Pfisterer P3PS panel sockets, rear or top cable entry |
| Auxiliary control supply | 24 / 48 VDC from the converter auxiliary distribution |
| Maximum breaking / safety trip time | 75 ms protection trip, 500 ms safety trip |
| Cabinet rating | IP54, RAL 7035 finish, sound pressure level < 75 dB(A) |

ABB IGCT Module | ABB ACS6000 | ABB PCS6000 | PPD

ABB IGCT Module | ABB ACS6000 | ABB PCS6000 | PPD

ABB IGCT Module | ABB ACS6000 | ABB PCS6000 | PPD