GE IC200BEM003 | Industrial Network Controller Asset

$695.00

The GE Fanuc IC200BEM003 sits inside the VersaMax control architecture as a dedicated PROFIBUS-DP communication interface between the PLC system and distributed field devices.
Brand model:GE Fanuc 
Product Name:IC200BEM003
Warranty: 1 year
Origin:USA
HS code:85389000.00
Inventory: Spot/Futures
Goods condition: Brand new
Delivery time: 3-4days/1month

Brand: Model/SKU: GE IC200BEM003

Get a Quote / Inquiry

Phone/WhatsApp/Wechat:
WeChat QR Code WhatsApp

Description

  1. GE IC200BEM003 | Industrial Network Controller Asset

 

Unboxing & Physical Snapshot

  • Brand & Model: GE Fanuc VersaMax IC200BEM003
  • Product Type: PROFIBUS-DP Master Module for VersaMax PLC systems.
  • Approximate Physical Dimensions: 4.3 × 2.63 × 1.96 in (110 × 66.8 × 50 mm)
  • Estimated Shipping Weight: Approximately 3.0 lb (1.36 kg) including packaging.
  • Mounting Style: VersaMax carrier-mounted module assembly
  • Communication Interface: PROFIBUS-DP via 9-pin D-sub connector
  • Front Panel Features:
    • Status LED indicators
    • Network activity indicators
    • Module identification label
    • Communication connector access
  • Memory/Data Handling: Supports up to 3,584 bytes input and 3,584 bytes output data under supported CPU configurations.
  • What’s in the Box:
    • GE Fanuc IC200BEM003 PROFIBUS-DP Master Module
    • Anti-static ESD shielding bag
    • Protective foam packaging
    • Installation documentation when supplied
    • Mounting accessories if included

 

Product Introduction

The GE Fanuc IC200BEM003 sits inside the VersaMax control architecture as a dedicated PROFIBUS-DP communication interface between the PLC system and distributed field devices. The module occupies a carrier position within the I/O structure and connects through the VersaMax backplane while providing external network access through the PROFIBUS connector (which is critical when maintaining legacy production cells with validated fieldbus layouts).

This communication module is often retained as a maintenance spare because replacing a network interface can affect an entire machine segment. Verify the firmware revision, PLC CPU compatibility, and PROFIBUS configuration file before installation. Check the 9-pin connector carefully. Bent pins or damaged shielding can create intermittent communication faults that are difficult to diagnose.

 

Core Technical Specifications

Parameter Value
Manufacturer GE Fanuc / GE Intelligent Platforms
Model Number IC200BEM003
Product Family VersaMax
Module Type PROFIBUS-DP Master Module
Network Protocol PROFIBUS-DP
Maximum Slave Devices Up to 125 PROFIBUS-DP slave devices
Data Capacity Up to 3,584 bytes input / 3,584 bytes output
Data Rate 9.6 kbaud to 12 Mbaud
Connector Type 9-pin D-sub
Power Supply Backplane supplied
Current Consumption Approximately 450 mA
Isolation Frame ground: 250 VAC; network to backplane: 1,500 VAC for 1 minute
Mounting Method VersaMax carrier installation
Operating Temperature Industrial temperature range (application dependent)
Cooling Method Passive cabinet airflow
Configuration Method Software configuration through supported GE programming tools
GE IC200BEM003

GE IC200BEM003

 

Global Compliance & Industry Certifications

Expected regulatory approvals for the GE Fanuc IC200BEM003 communication module may include:

  • CE Mark — indicates conformity with applicable European EMC and safety requirements when installed within an approved system.
  • UL/cUL Listed or Recognized Component — commonly associated with industrial control equipment assemblies.
  • RoHS Compliance — applies to applicable manufacturing revisions.
  • IEC 61131-related industrial control practices — relevant to PLC system installation environments.
  • ATEX/IECEx — not normally a standalone certification for this module; requires evaluation of the complete hazardous-area control system.
  • Marine approvals such as DNV GL — only applicable if the complete equipment package has been specifically certified.

PROFIBUS modules operate in electrically noisy industrial environments. EMC certification matters because it demonstrates that the device has been evaluated for conducted and radiated interference limits, reducing the chance of unexpected network disruptions.

Verify specific lot certifications with OEM.

 

Long-Term Storage & Asset Preservation Guide

  • Keep the sealed inside its original anti-static (ESD) bag until deployment. The backplane connector contacts and communication interface are sensitive to contamination.
  • Maintain warehouse humidity below 60% RH. Excess moisture can accelerate oxidation on connector contacts and degrade PCB protective coatings over long storage periods.
  • Store the module in a dry cabinet away from welding areas, chemical vapors, and high-dust environments (these conditions frequently cause communication hardware failures years later).
  • Perform periodic inventory inspections. Record part number, serial number, firmware revision, and packaging condition before returning the spare to storage.
  • Avoid stacking heavy equipment on the module carton. Mechanical stress can damage the carrier interface or distort the housing.

 

Physical Installation Prerequisites

  • Install the only on a compatible GE VersaMax carrier assembly.
  • Confirm that the carrier, CPU configuration, and PROFIBUS network design support the module.
  • Leave at least 50 mm clearance above and below the installed rack area when cabinet cooling depends on natural convection.
  • Verify protective grounding of the control cabinet before connecting communication wiring.
  • Use shielded PROFIBUS cable with proper grounding practices.
  • Install network termination correctly at both ends of the PROFIBUS segment.
  • Avoid forcing the module into the carrier. Align the retaining features and connector guides before applying insertion pressure.

 

Buyer’s FAQ (Logistics & Compliance Focus)

Q: What HS Tariff Code is typically used for the GE ?

A: Industrial communication modules are commonly evaluated under HS classifications related to electrical control equipment, often within headings such as 8537, depending on the product function and importing-country interpretation. Confirm the final tariff classification with a customs broker before shipment.

Q: Does Country of Origin affect procurement approval for this PLC communication module?

A: Yes. COO information affects customs declarations, supplier qualification records, and asset traceability. Preserve the module label, serial number, and purchase documentation together.

Q: Should this module be shipped with insurance coverage?

A: Recommended. Although compact, the contains communication electronics and precision connectors that can suffer concealed transit damage. Insure shipments according to replacement cost.

Q: Does the arrive with the latest firmware pre-loaded?

A: Not necessarily. Firmware and configuration depend on the specific hardware revision and application history. Verify compatibility with the existing VersaMax CPU, PROFIBUS master configuration, and approved machine documentation before installation.

mingpian