GE IS200EPSMG1AED | Exciter Power Supply Module For Mark VI Turbine Control System

$2,650.00

The IS200EPSMG1AED feeds stable excitation power to the generator field winding; failure here stops generator output entirely, leaving your facility facing costly lost production windows.
Brand model:GE
Product Name:IS200EPSMG1AED
Warranty: 1 year
Origin:USA
HS code:85389000.00
Inventory: Spot/Futures
Goods condition: Brand new
Delivery time: 3-4days/1month

Categories: , Model/SKU: GE IS200EPSMG1AED-1

Description

  • Brand: GE
  • Full Model Number: IS200EPSMG1AED
  • Lifecycle Status: Obsolete OEM part, available from stocked surplus inventory
  • Core Function in System: Exciter power supply board within Mark VI turbine control rack, delivers regulated excitation power to field circuits
  • Top 3 Hardcore Specs: Rack mounted form factor, 24 VDC auxiliary input, internal fault detection circuitry
  • Condition & Lead Time: Surplus tested stock, ships within 24 business hours for urgent plant outage work

 

Technical Intro & Downtime Impact

When this exciter power supply board develops an internal short or intermittent fault, your gas turbine Mark VI rack can trigger unplanned generator trip. Even sporadic power glitches on the exciter path force full turbine shutdown. The IS200EPSMG1AED feeds stable excitation power to the generator field winding; failure here stops generator output entirely, leaving your facility facing costly lost production windows. (—vibration from nearby turbine machinery can accelerate solder joint fatigue on older installed boards.)

Shortening MTTR on turbine outages matters heavily for scheduled maintenance windows. This board operates at standard rack‑internal temperature range 0 °C to 60 °C. It accepts 24 VDC rack auxiliary supply and distributes conditioned power for the exciter control path. No on‑board user memory exists on this specific power card, so you will not need to reload application logic after physical swap. For cabinets with poor internal airflow, allow extra periodic inspection cycles, as higher ambient temperatures can shorten service life over multi‑year runs.

 

Dynamic Emergency Swap & Configuration Guide

Pre‑Swap Prep Lock out the Mark VI control rack main cabinet power at the upstream breaker. Grab anti‑static wrist strap, standard flat‑head screwdriver for the retaining fasteners. Confirm plant lock‑out‑tag‑out procedures are fully completed before opening the rack door.

Removal Loosen the two captive spring fasteners located at the front face of the IS200EPSMG1AED board. Grip the integrated board extraction levers, and gently pull the circuit card straight outward from its backplane slot. Do not twist while removing; twisting can scratch the gold‑plated backplane connector pins.

Installation & Configuration Align the circuit board with the rack guide rails, push firmly until the card seats fully into the backplane. Tighten the front captive fasteners. There are no DIP switches or node address settings for this power supply module. Double‑check adjacent boards have not shifted during insertion.

Power‑On Self‑Test (POST) Restore cabinet auxiliary 24 VDC power. Watch the front‑panel status LED. Steady green indicates normal operating condition. Flashing amber points to backplane contact issues; solid red LED confirms an internal board fault. If red stays active immediately after power‑up, shut power down and re‑seat the module one more time.

GE IS200EPSMG1AED

GE IS200EPSMG1AED

Quality Assurance & Testing SOP

Each IS200EPSMG1AED unit pulled from our warehouse stock first goes through OEM anti‑counterfeit visual inspection. Technicians verify board silkscreen labels, component layout, and original GE part marking against known factory reference samples. We then mount the board inside our Mark VI test rack to run full power‑on self‑test. Technicians record LED startup behavior and monitor stable 24 VDC input loading across a one‑hour continuous run cycle. Controlled I/O and power‑path simulation checks confirm the exciter power output stays within published voltage tolerances. After testing finishes, each board gets wrapped in static‑shield packaging before final shipment. We also document test results in our internal log for traceability. (Minor cosmetic surface marks on PCB edge connectors are normal for surplus hardware and do not impact electrical performance.)

 

Maintenance & Reliability FAQ

Is this a direct drop‑in replacement, or does it require a firmware flash? This power supply hardware requires no firmware update. It is a direct physical drop‑in for existing IS200EPSMG1AED slots inside your Mark VI rack. No controller logic changes are needed for the swap.

Is it safe to hot‑swap this module while the system is running? Hot‑swapping is not recommended. Even though the board receives auxiliary rack power, pulling it live will interrupt exciter power feed and trigger immediate generator trip. Always perform full rack auxiliary power shutdown before removal.

Will replacing this exciter power board cause my current program to be lost? Program logic resides on separate Mark VI processor boards, not on the IS200EPSMG1AED power supply. Your existing turbine control program will remain intact after replacement. Still, keep a recent offline backup saved on your engineering workstation as standard site practice.

What are the warranty terms if the unit fails post‑installation? Our stocked surplus carries a 12‑month limited warranty from shipping date. The warranty covers internal electrical failures. Damage caused by field over‑voltage, cabinet flooding, physical impact or improper ESD handling at your plant falls outside warranty coverage.

 

mingpian
xcd