Schneider TSXDSZ08R5 | Industrial PLC Replacement Module

$1,158.00

The Schneider TSXDSZ08R5 mounts into the Modicon TSX Micro automation platform as a discrete relay output expansion module. Cabinet installation quality matters here.
Brand model:Schneider 
Product Name:TSXDSZ08R5
Warranty: 1 year
Origin:USA
HS code:85389000.00
Inventory: Spot/Futures
Goods condition: Brand new
Delivery time: 3-4days/1month

Brand: Model/SKU: Schneider TSXDSZ08R5

Get a Quote / Inquiry

Phone/WhatsApp/Wechat:
WeChat QR Code WhatsApp

Description

  1. Schneider TSXDSZ08R5 | Industrial PLC Replacement Module

 

Unboxing & Physical Snapshot

  • Model & Brand: Schneider Electric TSXDSZ08R5 Modicon TSX Micro Relay Discrete Output Module. This module provides eight relay outputs through a screw terminal block interface for Modicon TSX Micro automation platforms.
  • Product Type: PLC discrete relay output module.
  • Physical Dimensions (Approximate W × H × D): 80 × 120 × 40 mm (3.15 × 4.72 × 1.57 in.).
  • Estimated Shipping Weight: Approximately 0.36 kg (0.79 lb) for the module; approximately 0.5–0.8 kg with protective packaging.
  • What’s in the Box:
    • Schneider Electric TSXDSZ08R5 relay output module
    • Screw terminal connection interface
    • Protective packaging
    • Product identification label
    • Anti-static protection where applicable
    • Documentation if supplied

 

Product Introduction

The Schneider TSXDSZ08R5 mounts into the Modicon TSX Micro automation platform as a discrete relay output expansion module. Cabinet installation quality matters here. The module relies on proper rack positioning, clean backplane engagement, and stable environmental conditions because relay contacts and terminal connections are directly involved in field device switching (which is critical for long-running machine control systems).

This module provides eight normally open relay outputs for controlling external actuators, contactors, and other field devices. It supports AC and DC switching applications within specified voltage limits. Check the terminal screws before commissioning. A loose field connection can create contact heating, intermittent operation, or unexpected equipment stops.

 

Core Technical Specifications

Parameter Value
Manufacturer Schneider Electric
Model Number TSXDSZ08R5
Product Family Modicon TSX Micro
Product Type Relay discrete output module
Number of Outputs 8 relay outputs
Output Connection Screw terminal block
Contact Type Normally Open (NO)
Output Voltage Range 19–264 VAC / 10–34 VDC
Thermal Current 3 A
Response Time <10 ms
Current Consumption 85 mA
Power Dissipation 1.5 W
Isolation Voltage 1500 V for 1 second
Insulation Resistance ≥10 MΩ
Communication Interface TSX Micro backplane
User Memory None
Firmware Storage None
Cooling Method Natural convection
Operating Environment Industrial control cabinet
Approximate Dimensions 80 × 120 × 40 mm
Weight Approx. 0.36 kg
Schneider TSXDSZ08R5

Schneider TSXDSZ08R5

 

Global Compliance & Industry Certifications

Expected compliance considerations for the Schneider TSXDSZ08R5 include:

  • CE Mark — applicable as part of the compliant Modicon TSX Micro automation system.
  • UL/cUL Recognition — may apply depending on system configuration and installation requirements.
  • RoHS Status — verify according to manufacturing date code and documentation. Some older TSX Micro products may not meet current environmental requirements.
  • ATEX/IECEx — not applicable as a standalone module unless installed within a certified hazardous-area control system.
  • Marine approvals (DNV GL) — not typically applicable.

CE compliance is important for relay output modules because switching loads can generate electrical noise and transient conditions that affect surrounding automation equipment.

Verify specific lot certifications with OEM.

 

Long-Term Storage & Asset Preservation Guide

Keep the inside its original anti-static packaging during storage. Avoid exposing the terminal contacts and connector areas to warehouse dust or moisture.

Maintain storage humidity below 60% RH. Extended exposure to humidity can oxidize relay contacts and reduce connection reliability.

Inspect before installation. Check the terminal block, housing condition, connector surfaces, and identification label. For legacy PLC modules, confirm the exact hardware revision before replacing an installed unit (older automation platforms often contain multiple generations of compatible-looking modules).

Store away from vibration sources and corrosive chemicals.

 

Physical Installation Prerequisites

  • Install only in a compatible Modicon TSX Micro rack/backplane system.
  • Verify module addressing and I/O configuration before replacement.
  • Disconnect power before removing or inserting the module.
  • Ensure the backplane connector is clean and undamaged.
  • Tighten field wiring terminals according to recommended torque values.
  • Provide cabinet ventilation for natural convection cooling.
  • Maintain approximately 50 mm clearance around ventilation areas where cabinet design permits.
  • Connect protective grounding according to the machine control cabinet design.
  • Separate relay output wiring from sensitive analog signal wiring when possible.

 

Buyer’s FAQ (Logistics & Compliance Focus)

Q: What HS Tariff Code is commonly used for the Schneider ?

A: PLC I/O modules are commonly classified under HS 8538 as parts for electrical control equipment, although some customs authorities may evaluate them under broader automation equipment classifications. Confirm the final HS code with the importing customs authority.

Q: Does Country of Origin (COO) affect importing this TSX Micro module?

A: Yes. COO affects customs declarations, duty calculations, warranty records, and industrial asset traceability. The invoice, packing list, and product label information should remain consistent.

Q: Is shipping insurance recommended for the ?

A: Recommended. The module is lightweight, but relay contacts, terminal blocks, and internal PCB assemblies can be damaged by impact, moisture, or improper handling during international transport.

Q: Does the Schneider include the latest firmware pre-loaded?

A: No. This is a relay output module and does not contain user firmware or application memory. The PLC CPU manages logic execution, while the provides the physical relay switching interface.

Lifecycle Note: Schneider Electric lists the as discontinued for new commercialization, with service support continuing according to lifecycle policy. Existing installations should maintain verified spare inventory because direct replacements may not be available.