DEIF DLQ144-PC-NB | Analog Marine Panel Meter and Indicator

$3,540.00

The DEIF DLQ144-PC-NB belongs to the DLQ family of illuminated switchboard instruments designed for local measurement indication.
Brand model:DEIF
Product Name: DLQ144-PC-NB
Warranty: 1 year
Origin:USA
HS code:85389000.00
Inventory: Spot/Futures
Goods condition: Brand new
Delivery time: 3-4days/1month

Brand: Model/SKU: DEIF DLQ144-PC-NB

Description

  • Brand: DEIF

  • Full Model Number: DLQ144-PC-NB

  • Lifecycle Status: Discontinued product family; the DEIF DLQ-series datasheet is marked no longer for sale

  • Core Function: Illuminated analog panel indicator for marine and industrial machinery; the exact display scale depends on the ordered configuration

  • Top 3 Technical Specs: 144 × 144 mm nominal instrument size; 24 V AC/DC illumination; Class 1.5 accuracy for the DLQ series

  • Additional Specifications: 137 × 137 mm nominal panel cutout with specified tolerance; approximately 0.385 kg family-datasheet weight; configured input range and scale require verification

  • Stock & Condition: Physical availability, condition grade, identification markings, functional test results, and dispatch lead time subject to confirmation

 

Obsolescence & Supply Chain Deep Dive

When a marine control panel loses its original analog indicator, obtaining a replacement with the correct scale and electrical input can become a maintenance bottleneck. The DEIF DLQ144-PC-NB belongs to the DLQ family of illuminated switchboard instruments designed for local measurement indication. The 144 mm format supports panel-mounted installation, while the PC designation identifies a center-pointer configuration. The NB variant uses a standard pointer without separate direct pointer illumination. For propulsion and machinery applications, the displayed value may represent rotational speed, pitch, or another configured measurement. The original scale, signal range, and complete ordering information must therefore be checked before purchase. The manufacturer’s published DLQ-series datasheet also identifies the family as no longer for sale, making the identification of suitable remaining stock important for legacy installations.

For facilities retaining existing marine instrumentation, replacing an individual meter can avoid the engineering expense of redesigning the panel or migrating the entire control system. The potential return on investment comes from reduced modification work, shorter maintenance interventions, and less downtime exposure. Total cost of ownership (TCO) should account for the replacement price, international freight, installation labor, signal verification, and any panel machining. A matching physical size alone is insufficient. The replacement must also reproduce the intended measurement range, scale markings, electrical input characteristics, and illumination requirements. When factory-new supply is limited, documented surplus stock can provide a practical maintenance option—provided the actual unit’s configuration and condition are verified before the purchase order is released.

 

Compatibility & Replacement Matrix

Evaluation Item

Engineering and Procurement Guidance

Replacement classification

Conditional drop-in replacement when the input configuration, scale, dimensions, connections, and illumination requirements match

Software compatibility

Not applicable to the standard analog indicator; no firmware flash should be assumed necessary

Hardware modification

Normally unnecessary for a matching configuration; panel modification may be required if dimensions or mounting arrangements differ

Nominal instrument size

144 × 144 mm

Nominal panel cutout

137 × 137 mm with the manufacturer-specified tolerance; verify against the actual panel drawing

Electrical compatibility

Confirm the measuring input type and range. The family supports different voltage and current configurations, depending on the order specification

Illumination supply

24 V AC/DC nominal for the documented DLQ configuration; verify the actual unit’s rating

Estimated replacement time

Approximately 0.5–2 technician-hours for a straightforward exchange and basic functional verification, excluding access, isolation, and additional commissioning

Cost estimate

No firmware or software expense expected. Budget 0.5–2 technician-hours at the site’s labor rate, plus the unit, freight, and any required panel work

Final acceptance

Confirm pointer response, scale correspondence, illumination, and measurement accuracy against the approved application requirements

DEIF DLQ144-PC-NB

DEIF DLQ144-PC-NB

 

Field Traps to Check Before Ordering

Scale and input-range mismatch

Two visually similar analog indicators may have different scale markings or electrical input configurations. Check the installed unit’s nameplate, terminal connections, scale drawing, and original equipment documentation. Some DLQ configurations use voltage inputs; others use current inputs. Do not apply a generic input specification to the DLQ144-PC-NB without confirming the particular unit. Where applicable, also verify whether the scale represents positive and negative values, zero-centered readings, or a unidirectional measurement.

Panel dimensions and illumination wiring

The nominal face dimension does not equal the panel cutout. Confirm the existing aperture, mounting depth, terminal clearance, and retention arrangement before installation. For the documented DLQ family, illumination uses a separate 24 V AC/DC supply, with screw-terminal connections specified in the datasheet. Verify the voltage, polarity requirements where applicable, wiring arrangement, and illumination current before energizing. Do not assume that the existing wiring matches a replacement with a different configuration.

 

Quality Assurance & Testing SOP

The DEIF DLQ144-PC-NB is an analog panel instrument, not a PLC or DCS I/O module. Its QA procedure should focus on identification, physical condition, scale integrity, electrical input response, and illumination rather than diagnostic LEDs or digital communication. Each test must use the applicable configuration and recorded acceptance criteria.

QA Stage

Required Action

Acceptance Evidence

Identification inspection

Examine DEIF branding, model designation, nameplate, serial or identification markings, and available traceability records

Identification photographs and inspection checklist

OEM anti-counterfeit visual screening

Compare label format, markings, connector construction, casing details, and visible workmanship against available reference information

Recorded observations and documented discrepancies; visual screening alone does not establish authenticity

Mechanical inspection

Check the bezel, glass, pointer, scale face, rear terminals, mounting hardware, and casing for damage or unauthorized modification

Condition report and photographs

Illumination test

Apply the specified illumination supply within the documented operating limits

Consistent illumination, with no abnormal flickering or visible damage

Analog input test

Apply a known electrical input using a suitable calibrated signal source matched to the configured input type

Recorded input values and corresponding pointer positions

Pointer and scale verification

Check zero, intermediate points, full-scale response, and direction of travel against the specified scale

Recorded readings evaluated against the applicable accuracy limits

Input-load verification

Where required, measure the instrument’s input burden against the specification for the particular configuration

Measured input burden and acceptance result

POST and LED checks

Digital POST and RUN/ERR LED diagnostics are not applicable to this standard analog instrument; verify pointer movement and illumination instead

Recorded analog-function test results

Final inspection and packing

Recheck the terminals, scale face, mounting components, and ESD or mechanical protection requirements as applicable

Final inspection record and packing confirmation

QA acceptance rule: A visual inspection or successful illumination test does not establish measurement accuracy. If a calibrated signal source and suitable reference equipment are unavailable, disclose the testing limitation before shipment. Functional test records should identify the actual unit and the configuration tested; generic series specifications are not a substitute for unit-level evidence.

 

Procurement & Lifecycle FAQ

Is the DEIF DLQ144-PC-NB genuinely in stock, and what is the emergency-shipping cutoff?

Actual availability must be confirmed against physical inventory. Request current photographs of the specific unit, its identification label, the quoted condition, and the earliest confirmed dispatch date. The emergency-shipping cutoff depends on order approval, payment or credit clearance, packaging, export documentation, and carrier collection times. Same-day dispatch should be confirmed in writing rather than assumed.

How do you verify the condition and authenticity of this discontinued DEIF instrument?

Request photographs of the actual meter, nameplate, scale markings, rear connections, and mounting hardware. Ask for a condition declaration and the results of any completed functional tests. Where OEM traceability is required, request supporting documentation. Visual inspection can identify inconsistencies, but it cannot independently guarantee authenticity. The quotation should distinguish new surplus, used equipment, and tested refurbished stock.

What electrical and configuration details must engineering verify before issuing the PO?

At minimum, confirm the exact model designation, measuring input type, measurement range, scale artwork, panel dimensions, terminal arrangement, and illumination supply. If the application is a marine propulsion system, also verify the displayed RPM or pitch range and the zero or direction-of-travel convention. Do not approve a replacement solely because the faceplate dimensions match.

What warranty and return terms apply to the DEIF DLQ144-PC-NB?

The warranty duration and return conditions should be documented in the supplier’s quotation or pro forma invoice. Confirm coverage for functional defects, the dead-on-arrival reporting period, return authorization requirements, and any exclusions for installation damage or unauthorized alteration. For discontinued instruments, agree on the acceptance criteria and available test evidence before shipment.

Is replacing the existing more economical than upgrading the control panel?

A verified like-for-like replacement may avoid panel redesign, new instrumentation, rewiring, and associated commissioning work. The financial case depends on equipment condition, spare availability, downtime exposure, and the remaining service requirements of the installation. Compare the total replacement cost with the cost of a wider retrofit, including engineering, panel modifications, commissioning labor, and the planned outage. If exact configuration matching cannot be established, evaluate the replacement risk before committing to the lower-cost option.