Foxboro RH926KE | Two Position FCM FBM Baseplate for I/A Series

$3,456.00

The Foxboro RH926KE provides a two-position platform for supported FCMs and standard 200 Series FBMs.
Brand model:Foxboro 
Product Name:RH926KE
Warranty: 1 year
Origin:USA
HS code:85389000.00
Inventory: Spot/Futures
Goods condition: Brand new
Delivery time: 3-4days/1month

Brand: Model/SKU: Foxboro RH926KE

Description

  • Brand: Foxboro
  • Full Model Number: RH926KE
  • Product Type: Standard 200 Series FCM/FBM modular baseplate
  • Lifecycle Status: Listed in Foxboro Evo product documentation; current production and support status require confirmation
  • Core Function: Mounting platform and communication backplane for supported Fieldbus Communication Modules (FCMs) and Fieldbus Modules (FBMs)
  • Top 3 Technical Specs:
    • Module Positions: 2
    • Mounting Orientation: Horizontal DIN rail
    • Module Compatibility: FCM100E/FCM100Et or standard 200 Series FBMs, including supported mixed configurations
  • System Interface: Module fieldbus and primary/secondary 24 VDC power connections within the supported 200 Series architecture
  • Baseplate Address: Hardwired baseplate address 0; FBM positions use addresses 1 and 2
  • Identification: No baseplate identification DIP switch
  • Predecessor Part Number: P0926KE
  • Stock & Condition: Confirm inventory, physical condition, revision markings, and dispatch schedule during quotation

Foxboro documentation identifies RH926KE as the horizontal two-position FCM/FBM baseplate that supersedes P0926KE.

 

Obsolescence & Supply Chain Deep Dive

When a fieldbus baseplate fails in an established distributed control system, finding the correct mounting and communication interface becomes a maintenance priority. The Foxboro RH926KE provides a two-position platform for supported FCMs and standard 200 Series FBMs. Its passive backplane connects the installed modules to the system’s fieldbus and associated power interfaces. The documented predecessor is P0926KE, making RH926KE an important part number to check when maintaining an older installation. However, the baseplate is not a standalone analog signal conditioner or an independent HART isolation device. Confirm the exact model, mounting orientation, installed modules, and system generation before releasing a purchase order.

For plant maintenance and procurement teams, obtaining a matching baseplate can reduce the need for cabinet redesign or replacement of an otherwise serviceable I/O subsystem. The total cost of ownership should account for the spare part, technician labor, module transfer, wiring inspection, fieldbus verification, and commissioning. Retaining the existing architecture may be less expensive than migrating the entire I/O arrangement, especially when the failure is limited to the baseplate. That advantage depends on correct compatibility verification. A mechanically similar baseplate from another Foxboro family may use a different mounting layout or module interface. Confirm the application requirements and current system documentation before choosing a substitute.

 

Compatibility & Replacement Matrix

Use the complete part number and installed module arrangement when evaluating RH926KE replacements.

Replacement Scenario Compatibility Classification Estimated Labor and Planning
RH926KE replacement with matching horizontal mounting, module configuration, and system interface Conditional Drop-in Replacement Approximately 2–4 technician hours for isolation, replacement, reconnection, and initial checks
Replacement of predecessor P0926KE with Documented Successor; Verify Installation Approximately 2–4 technician hours, subject to cabinet access and installed configuration
Replacement with vertical baseplate RH926KH Mounting and Wiring Review Required Approximately 4–8 technician hours if orientation changes or additional wiring work is required
Migration to a different baseplate family or I/O architecture Engineered Hardware Migration Approximately 8–24+ engineering and technician hours, depending on redesign and validation requirements

These are preliminary planning allowances, not manufacturer-prescribed installation times. Actual labor depends on cabinet accessibility, field wiring, module type, redundancy requirements, and site commissioning procedures.

Foxboro RH926KE

Foxboro RH926KE

 

 

Quality Assurance & Testing SOP

The pre-shipment QA process should distinguish physical inspection of the baseplate from functional testing of a complete FCM/FBM assembly. Since the baseplate provides mounting and backplane connections, it does not perform analog signal conversion independently.

Visual Inspection and Manufacturer Identification

  • Perform an OEM anti-counterfeit visual inspection of the Foxboro branding, designation, and available identification markings.
  • Compare the part number and physical configuration against the purchase specification and available manufacturer documentation.
  • Inspect the backplane connectors, module slots, rail-mounting features, and terminal interfaces for physical damage.
  • Check for corrosion, contamination, cracked connectors, damaged contacts, heat discoloration, or signs of unauthorized repair.
  • Verify the mounting orientation and compare the connector layout with the approved reference configuration.
  • Photograph the identification markings and overall baseplate condition.

Power-On and Backplane Verification

  • Inspect the bench setup and confirm that the installed FCM/FBM modules are supported by the .
  • Verify that the test configuration uses the applicable system power and communication interfaces.
  • Perform power-on checks using the complete compatible assembly rather than treating the baseplate as a standalone powered device.
  • Review the status indicators on the installed modules, including any documented power, communication, or diagnostic indications.
  • Check for unexpected module faults, communication errors, or intermittent connection symptoms.
  • Record the module types, test configuration, and results.

Procurement & Lifecycle FAQ

Is the Foxboro in stock, and what is the cutoff for emergency shipping?

Availability depends on the inventory allocated to your order. Confirm the exact model, quantity, condition, and inspection requirements when requesting a quotation. Emergency dispatch depends on payment clearance, completion of agreed checks, packaging, and the carrier’s collection schedule. Request a written dispatch commitment when the part is needed for an urgent maintenance window.

How do you verify the authenticity and condition of baseplates?

The inspection process should include manufacturer identification, part-number verification, connector inspection, and checks for physical damage or unauthorized repair. Functional checks should use a compatible FCM/FBM assembly when available. Request current photographs and the applicable inspection report before placing the order. Visual inspection alone cannot establish complete backplane or system functionality.

Are firmware or configuration compatibility issues relevant before issuing the purchase order?

Firmware flashing is not normally the primary concern for a passive baseplate. The main checks involve the supported module family, controller architecture, mounting orientation, fieldbus interface, and module addressing. Verify the installed FCM/FBM arrangement and any applicable configuration requirements with the engineering team before replacing the hardware.

What warranty and return terms apply to the Foxboro ?

Warranty coverage and return eligibility should be confirmed in writing on the quotation or pro forma invoice. Review the warranty period, covered defects, exclusions, claim procedure, and return authorization requirements before purchase. Confirm whether the allocated unit is new, surplus, or previously used, and obtain written confirmation of the condition and testing scope.

Should we replace the or migrate to another Foxboro I/O platform?

A matching replacement may be the more economical option when the existing Standard 200 Series installation remains suitable and compatible spares are available. A platform migration may be justified when lifecycle support, system architecture, or expansion requirements make continued maintenance impractical. Compare the replacement cost against engineering labor, wiring changes, configuration work, validation, and planned downtime. Any change affecting control or safety-related functions should follow the site’s formal engineering and commissioning procedures.

Foxboro FBMSVH | Original I/A Series Control Module
Foxboro P0926HW | Traceable Foxboro Evo Asset
Foxboro P0912XX | Foxboro DCS Cabinet Power Component
Foxboro FBM211 P0916BT | Original I/A Series Module
FOXBORO FBM242 | Original Process Automation I/O
Foxboro P0972KX | Original I/A Series Fiber Link Assembly
Foxboro FBM216 P0917XQ | Traceable I/A Series Module
mingpian