FOXBORO 33C-AJ-D | Nullmatic Pneumatic Temperature Transmitter

$2,650.00

The FOXBORO 33C-AJ-D belongs to the Model 33 Nullmatic temperature transmitter family, designed for process temperature measurement in applications such as vessels, reactors, heat exchangers, pipelines, and industrial ducts.
Brand model:FOXBORO
Product Name: 33C-AJ-D
Warranty: 1 year
Origin:USA
HS code:85389000.00
Inventory: Spot/Futures
Goods condition: Brand new
Delivery time: 3-4days/1month

Brand: Model/SKU: FOXBORO 33C-AJ-D

Description

  • Brand: FOXBORO
  • Full Model Number: 33C-AJ-D
  • System/Series Family: Foxboro Model 33 Nullmatic pneumatic temperature transmitter family
  • Core Function: Converts temperature changes detected by a thermal sensing system into a proportional pneumatic pressure signal for process indication and control.
  • Top 3 Hardcore Specs:
    • Standard output: 3–15 psig; alternative 3–27 psig and 0–30 psig ranges are documented for the Model 33 family.
    • Supply pressure: 20 psig normal supply; 35 psig maximum; minimum supply pressure must exceed the maximum output pressure by at least 4 psi.
    • Temperature range: Model 33 family supports spans from 50°F to 1,000°F, depending on the thermal system; specific bulb configurations and operating limits require verification.
  • Stock Status: Availability, new-surplus or refurbished condition, calibration status, and warranty require confirmation.

Identification note: Public listings provide conflicting electrical and pneumatic descriptions for 33C-AJ-D. The Foxboro Model 33 Nullmatic documentation describes a pneumatic transmitter. Confirm the exact nameplate, thermal assembly, and output configuration before purchasing; do not assume a 120 VAC supply applies to the required unit.

 

Commercial-Technical Deep Dive

When a legacy process temperature loop loses its transmitter, the immediate challenge is restoring a trustworthy measurement without changing the receiving control architecture. The FOXBORO 33C-AJ-D belongs to the Model 33 Nullmatic temperature transmitter family, designed for process temperature measurement in applications such as vessels, reactors, heat exchangers, pipelines, and industrial ducts. Its thermal sensing system converts temperature-driven pressure changes into a pneumatic output. For maintenance teams supporting older pneumatic control loops, matching the complete transmitter and thermal assembly is essential (the model suffix and installed sensing arrangement matter as much as the base designation).

The Model 33 uses a pilot-operated, null-balance force mechanism. Its documented standard output is 3–15 psig, proportional to the configured temperature range. Thermal response varies with the sensing element: published family data gives approximately 0.03 minutes for a bare stainless-steel bulb, 0.3 minutes for a 3/8-inch stainless-steel bulb in a well, and 0.7 minutes for a 3/4-inch stainless-steel bulb in a well, under specified test conditions. These figures are not interchangeable across configurations. Selecting the correct bulb, capillary, measuring span, and pressure output helps avoid slow indication, incorrect control response, and unnecessary recalibration. Before replacement, compare the installed instrument’s range and output with the receiving controller’s requirements.

 

Compatibility & Installation Traps

Migration/Compatibility

Treat FOXBORO 33C-AJ-D as a conditional replacement, not an automatically interchangeable instrument.

Confirm the following before installation:

  • Model and suffix: Match the complete 33C-AJ-D designation and the installed transmitter’s identification.
  • Thermal system: Verify bulb material, bulb diameter, immersion length, capillary length, and connection arrangement. Foxboro Model 33 documentation warns that thermal systems are not interchangeable between differently lettered transmitter models.
  • Temperature calibration: Match the lower and upper range limits, engineering units, and maximum process temperature.
  • Pneumatic interface: Confirm supply pressure, output pressure range, tubing connections, and the receiving controller or pneumatic instrument’s input requirements.
  • Installation dimensions: Check mounting bracket, process connection, thermowell fit, and available capillary routing space.

A firmware flash or digital communication handshake is not normally relevant to this pneumatic instrument family. However, changes to the control-loop configuration or pneumatic receiver settings may be needed if the replacement range differs from the installed unit.

Field Traps (Watch Out)

Thermal bulb and capillary mismatch: A transmitter with the wrong sensing assembly may produce incorrect readings or respond differently to process temperature changes. Check the full thermal-system configuration, not just the transmitter housing.

Incorrect pneumatic supply or output assumptions: The documented Model 33 family uses pneumatic connections, commonly with a 3–15 psig output. Do not connect the unit based on an unverified electrical rating or assume every suffix uses the same range. Verify the nameplate and applicable documentation before applying pressure.

FOXBORO 33C-AJ-D

FOXBORO 33C-AJ-D

Quality Assurance SOP

The following procedure defines a proposed pre-shipment inspection and testing protocol. It does not imply that a particular 33C-AJ-D unit has already passed these tests.

Incoming Inspection and Identification

  • Perform an OEM anti-counterfeit visual inspection, checking manufacturer markings, model designation, nameplate legibility, enclosure finish, fasteners, connectors, and signs of unauthorized modification.
  • Record the model number, serial number where present, thermal-system configuration, condition, and available traceability information.
  • Inspect the bulb, capillary, bellows enclosure, pneumatic ports, mounting hardware, and accessible seals for corrosion, physical damage, or leakage indicators.
  • Compare the unit’s calibration range and physical configuration with the customer’s installed instrument.
  • Photograph the nameplate and all relevant connections before packaging.

Pneumatic and Calibration Verification

  • Inspect the pneumatic supply and output ports; confirm that fittings match the documented arrangement.
  • Apply regulated air using a calibrated pressure source. The test supply must remain within the applicable OEM limits.
  • Verify zero and span at the agreed calibration points using an appropriate temperature simulator or controlled thermal test arrangement.
  • Measure output pressure across multiple points in the specified range. Record deviations against the acceptance criteria for the identified model and configuration.
  • Perform a leak test on the pneumatic connections and check for unstable output, abnormal hysteresis, or failure to return to zero.
  • Where practical, evaluate response time using the installed bulb and thermal well arrangement. Do not apply published response figures without accounting for sensing-element and installation differences.

Test Applicability and Release

POST, ERR/RUN LED checks, and digital communication handshake tests do not apply to the standard pneumatic Model 33 architecture. These tests should not be claimed as completed for this instrument.

Release the unit only after identification, inspection, and agreed calibration checks are documented. If suitable calibration equipment or the correct thermal assembly is unavailable, disclose the limitation and avoid describing the unit as fully tested or calibrated.

 

CRO-Driven Buyer FAQ

Is FOXBORO 33C-AJ-D obsolete, and how can I source an authentic replacement?

Confirm its current lifecycle and support status with the manufacturer or relevant technical documentation. For replacement sourcing, request nameplate photographs, serial or traceability details where available, condition disclosure, and calibration records. A matching label alone does not establish authenticity or operating condition.

Can 33C-AJ-D replace another Model 33 transmitter directly?

Only after confirming the complete designation, temperature span, pneumatic output, and thermal sensing assembly. The Model 33 family includes different bulb configurations and measuring ranges; similar housings do not prove that two instruments are interchangeable.

Does the transmitter support hot swapping?

Hot swapping is not the appropriate assumption for this pneumatic process instrument. Isolate the relevant process connection and pneumatic supply, depressurize the affected lines safely, and follow site procedures for hazardous fluids, hot surfaces, and stored pressure before removal.

What warranty and technical support should I expect?

Warranty duration and technical support scope should be stated in the quotation. Confirm whether coverage includes functional faults, calibration deviations, repair or replacement, and the return authorization process. Technical support should be based on the verified configuration rather than assumptions about an undocumented variant.

What details are required for an urgent quotation?

Provide the exact model number, quantity, nameplate photographs, required temperature range, output-pressure range, thermal bulb and capillary details, shipping destination, and required delivery date. Request written confirmation of stock, condition, calibration status, warranty, and dispatch timing before placing the order.

Foxboro P0926HW | Traceable Foxboro Evo Asset
Foxboro P0912XX | Foxboro DCS Cabinet Power Component
Foxboro FBM211 P0916BT | Original I/A Series Module
FOXBORO FBM242 | Original Process Automation I/O
Foxboro P0972KX | Original I/A Series Fiber Link Assembly
Foxboro FBM216 P0917XQ | Traceable I/A Series Module